AEEDL-006 utilizes the air enthalpy difference method with a dual-chamber setup (indoor + outdoor), supporting a wide testing range from -20°C to 60°C and airflow from 200 to 2000 CFM. It supports a wide temperature span (-20°C to 60°C), large airflow range (200–2000 CFM), and various refrigerants including R32 and R290. Ideal for evaluating cooling, heating, defrosting, and energy efficiency in compliance with GB 7725-2010 and ISO 5151/13253 standards.

  • Brand :

    HONGCE
  • Model :

    AEEDL-006
  • Certificate :

    Calibration certificate(cost additional)
  • Product Origin :

    China
  • Payment Method :

    L/C, T/T
  • Regular Packaging :

    Plywood

Air Conditioning Enthalpy Difference Method Laboratory

Multi-Refrigerant Air Conditioning Performance Test System

Product Introduction:

AEEDL-006 is a precision testing system designed for air conditioner performance evaluation. It includes an indoor test chamber, an outdoor simulation chamber, an air handling unit, and an intelligent measurement and control system. Key features include:

  • Environment Simulation:

Indoor 10~50℃ (simulating user end), outdoor -20~60℃ (simulating extreme climate), humidity control spans 35–90% RH, covering both humid and dry seasonal conditions.

  • Multi-parameter Synchronous Measurement and Control:

20 thermocouple channels (±0.1°C), WT333E power meter (±0.2%), and dual refrigerant pressure sensors for synchronized parameter tracking.

  • Refrigerant Flexibility:

Compatible with R22, R410a, R32, R290, R134a—supporting both traditional and eco refrigerants.

  • Automated Process:

Integrated software automates data collection, generates efficiency curves and diagnostic reports, and connects to MES systems. Improves testing efficiency by up to 50%.

 

Product Features:

  • Multi-refrigerant Compatible: Supports R32, R290; aligned with eco-friendly trends.
  • Extreme Temperature Adaptability: Operates reliably from -20℃ to 60℃.
  • High-Precision Control: Accurate monitoring of temperature, power, and airflow.
  • Customizable Design: Flexible adjustment of airflow, temperature, and sensor channels.
  • Global Standards: Certified to GB 7725-2010 & ISO 5151/13253。
  • Intelligent Unattended Operation: Remote monitoring with automatic alerts and maintenance.

 

International Reference Standards

GB 7725-2010, ISO 5151-2017 and ISO 13253-2017

 

Technical Parameters

Item Technical Details
Model AEEDL-006
Test Method Air Enthalpy Difference Method
Chamber Layout 1 Indoor Chamber + 1 Outdoor Chamber
Indoor Temp. Range 10–50℃
Outdoor Temp. Range -20–60℃
Relative Humidity 35–90%RH (Indoor/Outdoor)
Airflow Range (CFM) 200–2000 (Airflow Measurement Chamber)
Indoor Static Pressure -50–500Pa
Thermocouple Channels 20 (Indoor/Outdoor, -50~150℃)
Refrigerant Pressure Ports 2 (Outdoor Side)
Power Meter WT333E (1 Channel, ±0.2% Precision)
Variable Frequency Power 3-Phase, 45kVA
Supported Refrigerants R22, R410a, R32, R290, R134a
Compliance Standards GB 7725-2010, ISO 5151-2017, ISO 13253-2017
Test Items Rated Cooling/Heating, Max/Min Performance, Defrost, Freezing, Condensate Control, COP/SEER
leave a message
If you are interested in our equipment and want to know more details, please leave a message here. we will contact you as soon as possible.

Related Products

Air Conditioner Enthalpy Difference Test Laboratory
3HP Air Enthalpy Difference Test Laboratory

The multifunctional enthalpy difference laboratory provides comprehensive guarantee for the performance testing of air-conditioning equipment. It not only helps enterprises improve testing efficiency, but also effectively reduces testing costs. It is an ideal cooperation platform for performance evaluation in the air-conditioning industry.

Details
Air Conditioning Enthalpy Difference Method Laboratory
Air Conditioning Enthalpy Difference Method Laboratory

AEEDL-006 utilizes the air enthalpy difference method with a dual-chamber setup (indoor + outdoor), supporting a wide testing range from -20°C to 60°C and airflow from 200 to 2000 CFM. It supports a wide temperature span (-20°C to 60°C), large airflow range (200–2000 CFM), and various refrigerants including R32 and R290. Ideal for evaluating cooling, heating, defrosting, and energy efficiency in compliance with GB 7725-2010 and ISO 5151/13253 standards.

Details
refrigeration capacity test equipment
Precise Air Conditioning Enthalpy Difference Chamber with ±0.1℃ Temperature & Humidity Control

This precision air conditioning enthalpy difference test chamber is designed for high-precision air conditioning performance testing. It precisely controls temperature (±0.1°C) and humidity, ensuring stable and reliable test results. Its simple operation and precise results make it an ideal choice for air conditioning performance testing.

Details

leave a message

leave a message
If you are interested in our equipment and want to know more details, please leave a message here. we will contact you as soon as possible.
Submit

Our hours

Mon 11/21 - Wed 11/23: 9 AM - 8 PM
Thu 11/24: closed - Happy Thanksgiving!
Fri 11/25: 8 AM - 10 PM
Sat 11/26 - Sun 11/27: 10 AM - 9 PM
(all hours are Eastern Time)

Contact Us:hongce@iectester.com

Home

Products

whatsApp

contact