enen/ arar
Home Wall-mounted boiler testing equipment

Gas Wall-Mounted Boiler Comprehensive Test System

Gas Wall-Mounted Boiler Comprehensive Test System

Built for precision and compliance, the HCTE-WMBT005 gas wall-mounted boiler comprehensive test system delivers full-scope performance testing for gas wall-hung boilers. It complies with 8 key national and international standards, including NE483-1999, EN625-1996, and GB6932-2015. It supports performance verification, energy efficiency calibration and international certification pre-inspection in the R&D stage. Equipped with imported high-precision sensor modules, the wall mounted boiler comprehensive performance test system ensures data accuracy and traceability throughout the testing process.

  • Brand :

    hongce
  • Model :

    HCTE-WMBT005
  • Certificate :

    Calibration Certificate(Cost Additional)
  • Product Origin :

    China
  • Payment Method :

    L/C, T/T
  • Regular Packaging :

    Plywood

Gas Wall-Mounted Boiler Comprehensive Test System Features:

Integrated Multi-Component Testing:

Covers all four major components—proportional valves, water flow sensor, burner, and water channel accessories—with a single clamping setup for complete inspection.

Ultra-Fine Detection Capability: 

Water flow range of 0.1–30 L/min (1 L/min resolution); voltage range 0–30 V (0.1 V resolution) , ensure detection of even the smallest functional deviations.

Air Tightness Testing:

Supports proportional valve leak tests with adjustable gas pressure (requires external leak detector); includes fixtures and pressure regulators.

Burner-Specific Design:

Gas flow 2.5-25L/min, pressure - 3000~3000Pa adjustable, meeting the needs of both open-flame and energy-saving burners.

Intelligent interaction: 

Integrated PLC automation with a touch interface, real-time data curves, and USB-enabled historical data output.

 

National Reference Standards:

GB/T 16411-2022, GB 16914-2023 and CJ/T 395-2012

 

Product Use:

  • R&D Stage: 

Enterprise laboratories test the performance of new product components (such as 0.1V signal accuracy of water flow sensors, gas adaptability of burners).

  • Production Line: 

Enables batch quality inspection of complete units with multi-component testing—capable of testing over 80 units per day across multiple components—ensuring reliable defect screening.

  • Supplier Quality Control: 

Enables precise incoming material inspections to verify critical parameters like valve sealing and sensor resolution, ensuring stable upstream quality control.

 

Technical Parameters:

Parameter Technical Details
Model HCTE-WMBT005
Compliant Standards NE483-1999, EN625-1996, GB6932-2015 (8 Total)
Gas System  
Gas Flow Range 1–100 L/min (Class 0.5 Accuracy)
Gas Primary Pressure 0–10 kPa (Class 0.5 Accuracy)
Gas Secondary Pressure 0–5 kPa (Class 0.5 Accuracy)
Gas Temperature 0–50℃ (Class 0.5 Accuracy)
Water System  
Sanitary Water Flow 0–20 L/min (Class 0.5 Accuracy)
Heating Water Flow 0–40 L/min (Class 0.5 Accuracy)
Heating Outlet Temp 0–120℃ (Class 0.5 Accuracy)
Heating Return Temp 0–120℃ (Class 0.5 Accuracy)
Sanitary Inlet Temp 0–60℃ (Class 0.5 Accuracy)
Sanitary Outlet Temp 0–120℃ (Class 0.5 Accuracy)
Coolant Inlet Temp 0–100℃ (Class 0.5 Accuracy)
Coolant Outlet Temp 0–100℃ (Class 0.5 Accuracy)
Sanitary Inlet Pressure 0–1.0 MPa (Class 0.5 Accuracy)
Heating Return Pressure 0–1.0 MPa (Class 0.5 Accuracy)
Electrical System  
Unit Operating Voltage 0–300 V (Class 0.5 Accuracy)
Unit Operating Current 0–10 A (Class 0.5 Accuracy)
Unit Power 0–3 kW (Class 0.5 Accuracy)
Control & Performance  
Control Mode PC + PLC + 15-inch Touchscreen HMI
Data Storage ≥10,000 Records (USB/Ethernet Export)
Hydraulic Pressure Stability ≤±0.5% (Inlet Pressure Stabilizer)
Response Time (Imported Valves) ≤30 ms (Regulator/Solenoid Valve)
Ambient Temperature 0–40℃ (Non-condensing)
Protection Rating IP30 (Cabinet) / IP44 (Sensor)
leave a message
If you are interested in our equipment and want to know more details, please leave a message here. we will contact you as soon as possible.

Related Products

Gas Wall Mounted Boiler Comprehensive Testing System
Gas Wall-Mounted Boiler Comprehensive Test System

Built for precision and compliance, the HCTE-WMBT005 gas wall-mounted boiler comprehensive test system delivers full-scope performance testing for gas wall-hung boilers. It complies with 8 key national and international standards, including NE483-1999, EN625-1996, and GB6932-2015. It supports performance verification, energy efficiency calibration and international certification pre-inspection in the R&D stage. Equipped with imported high-precision sensor modules, the wall mounted boiler comprehensive performance test system ensures data accuracy and traceability throughout the testing process.

Details

leave a message

leave a message
If you are interested in our equipment and want to know more details, please leave a message here. we will contact you as soon as possible.
Submit

Our hours

Mon 11/21 - Wed 11/23: 9 AM - 8 PM
Thu 11/24: closed - Happy Thanksgiving!
Fri 11/25: 8 AM - 10 PM
Sat 11/26 - Sun 11/27: 10 AM - 9 PM
(all hours are Eastern Time)

Contact Us:hongce@iectester.com

Home

Products

whatsApp

contact