enen/ arar
Home Wall-mounted boiler testing equipment

Gas Wall-Mounted Boiler Comprehensive Test System

Gas Wall-Mounted Boiler Comprehensive Test System

Built for precision and compliance, the HCTE-WMBT005 gas wall-mounted boiler comprehensive test system delivers full-scope performance testing for gas wall-hung boilers. It complies with 8 key national and international standards, including NE483-1999, EN625-1996, and GB6932-2015. It supports performance verification, energy efficiency calibration and international certification pre-inspection in the R&D stage. Equipped with imported high-precision sensor modules, the wall mounted boiler comprehensive performance test system ensures data accuracy and traceability throughout the testing process.

  • Brand :

    hongce
  • Model :

    HCTE-WMBT005
  • Certificate :

    Calibration Certificate(Cost Additional)
  • Product Origin :

    China
  • Payment Method :

    L/C, T/T
  • Regular Packaging :

    Plywood

Gas Wall-Mounted Boiler Comprehensive Test System Features:

Integrated Multi-Component Testing:

Covers all four major components—proportional valves, water flow sensor, burner, and water channel accessories—with a single clamping setup for complete inspection.

Ultra-Fine Detection Capability: 

Water flow range of 0.1–30 L/min (1 L/min resolution); voltage range 0–30 V (0.1 V resolution) , ensure detection of even the smallest functional deviations.

Air Tightness Testing:

Supports proportional valve leak tests with adjustable gas pressure (requires external leak detector); includes fixtures and pressure regulators.

Burner-Specific Design:

Gas flow 2.5-25L/min, pressure - 3000~3000Pa adjustable, meeting the needs of both open-flame and energy-saving burners.

Intelligent interaction: 

Integrated PLC automation with a touch interface, real-time data curves, and USB-enabled historical data output.

 

National Reference Standards:

GB/T 16411-2022, GB 16914-2023 and CJ/T 395-2012

 

Product Use:

  • R&D Stage: 

Enterprise laboratories test the performance of new product components (such as 0.1V signal accuracy of water flow sensors, gas adaptability of burners).

  • Production Line: 

Enables batch quality inspection of complete units with multi-component testing—capable of testing over 80 units per day across multiple components—ensuring reliable defect screening.

  • Supplier Quality Control: 

Enables precise incoming material inspections to verify critical parameters like valve sealing and sensor resolution, ensuring stable upstream quality control.

 

Technical Parameters:

Parameter Technical Details
Model HCTE-WMBT005
Compliant Standards NE483-1999, EN625-1996, GB6932-2015 (8 Total)
Gas System  
Gas Flow Range 1–100 L/min (Class 0.5 Accuracy)
Gas Primary Pressure 0–10 kPa (Class 0.5 Accuracy)
Gas Secondary Pressure 0–5 kPa (Class 0.5 Accuracy)
Gas Temperature 0–50℃ (Class 0.5 Accuracy)
Water System  
Sanitary Water Flow 0–20 L/min (Class 0.5 Accuracy)
Heating Water Flow 0–40 L/min (Class 0.5 Accuracy)
Heating Outlet Temp 0–120℃ (Class 0.5 Accuracy)
Heating Return Temp 0–120℃ (Class 0.5 Accuracy)
Sanitary Inlet Temp 0–60℃ (Class 0.5 Accuracy)
Sanitary Outlet Temp 0–120℃ (Class 0.5 Accuracy)
Coolant Inlet Temp 0–100℃ (Class 0.5 Accuracy)
Coolant Outlet Temp 0–100℃ (Class 0.5 Accuracy)
Sanitary Inlet Pressure 0–1.0 MPa (Class 0.5 Accuracy)
Heating Return Pressure 0–1.0 MPa (Class 0.5 Accuracy)
Electrical System  
Unit Operating Voltage 0–300 V (Class 0.5 Accuracy)
Unit Operating Current 0–10 A (Class 0.5 Accuracy)
Unit Power 0–3 kW (Class 0.5 Accuracy)
Control & Performance  
Control Mode PC + PLC + 15-inch Touchscreen HMI
Data Storage ≥10,000 Records (USB/Ethernet Export)
Hydraulic Pressure Stability ≤±0.5% (Inlet Pressure Stabilizer)
Response Time (Imported Valves) ≤30 ms (Regulator/Solenoid Valve)
Ambient Temperature 0–40℃ (Non-condensing)
Protection Rating IP30 (Cabinet) / IP44 (Sensor)
leave a message
If you are interested in our equipment and want to know more details, please leave a message here. we will contact you as soon as possible.

Related Products

Gas Wall Mounted Boiler Comprehensive Testing System
Gas Wall-Mounted Boiler Comprehensive Test System

Built for precision and compliance, the HCTE-WMBT005 gas wall-mounted boiler comprehensive test system delivers full-scope performance testing for gas wall-hung boilers. It complies with 8 key national and international standards, including NE483-1999, EN625-1996, and GB6932-2015. It supports performance verification, energy efficiency calibration and international certification pre-inspection in the R&D stage. Equipped with imported high-precision sensor modules, the wall mounted boiler comprehensive performance test system ensures data accuracy and traceability throughout the testing process.

Details
Multi-Function Boiler Performance Test Bench
GB 4706 Electric Wall-Mounted Boiler Performance Test Bench

The GB 4706 Electric Wall-Mounted Boiler Performance Test Bench is a professional platform designed to fully test the safety, efficiency, and reliability of electric boilers. Built to meet the GB 4706 standard, it covers power, temperature control, and overall performance checks in one system.

Details
Smart-Control Gas Wall-Mounted Boilers
Comprehensive Gas Wall-Mounted Boiler Test Bench

The Comprehensive Gas Wall-Mounted Boiler Test Bench combines advanced automation, multi-standard compatibility, and precise measurement technology. It helps manufacturers and labs streamline testing processes, improve product quality, and ensure regulatory compliance—all in one reliable platform.

Details

leave a message

leave a message
If you are interested in our equipment and want to know more details, please leave a message here. we will contact you as soon as possible.
Submit

Our hours

Mon 11/21 - Wed 11/23: 9 AM - 8 PM
Thu 11/24: closed - Happy Thanksgiving!
Fri 11/25: 8 AM - 10 PM
Sat 11/26 - Sun 11/27: 10 AM - 9 PM
(all hours are Eastern Time)

Contact Us:hongce@iectester.com

Home

Products

whatsApp

contact